Automatic Wrist Blood Pressure health monitor with LCD Digital Display
Model no.: EC-U60BH
Specifications:
Display | LCD digital display | |
Measuring principle | Oscillometric method | |
Measuring localization | Wrist Type | |
Measurement range | Pressure | 0~299mmHg ( 0~39.9kPa) |
Pulse | 40~199 pulses/min | |
Accuracy | Pressure | +/-3mmHg (+/-0.4kPa) |
Pulse | +/-5% of reading | |
LCD indication | Pressure | 3 digits display of mmHg |
Pulse | 3 digits display | |
Symbol | Memory/Heartbeat/Low battery | |
Memory function | 2x90 sets memory of measurement values | |
Power source | 2 pcs AAA alkaline battery DC 3V; | |
Automatic power off | In 3 minutes | |
Main unit weight | Approx.122g(batteries not included) | |
Main unit size | L73mm x W65mm x H65mm | |
Main unit lifetime | 10,000 times under normal use | |
Battery life | Could be used for 300 times for normal condition | |
Accessories | Instruction manual, storage box | |
Operating environment |
Temperature | 5~40C |
Humidity | 15%~85%RH | |
Air pressure | 86kPa~106kPa | |
Storage environment |
Temperature -20C~55C ,Humidity :10% ~85% avoid crash, sun burn or rain during transportation. |
Applications:
1. Take a measurement one hour later after a meal
2. One hour before measurement, please don’t smoke, drink alcohol, tea or coffee
3. If over fatigue or emotional instability, please don’t measure.
4.10-20 minutes before measurement, keep quite state.
5. As far as possible, every day in the same time and condition, with same posture, 5 minutes interval between measurements.
6. If stored in low temperature environment, before using, first should put it in normal temperature environment place for at least one hour.
7. Don’t use it in mobile vehicles(cars,planes), otherwise it can’t correctly measure.
8. Please use it according to the instruction of temperature and humidity standard, or it may not be able to correctly measure.
9. When common arrhythmia (such as atrial premature, premature ventricular, atrial fibrillation) appears, measured values may not accurate or blood pressure can’t be measured.
Quick Detail:
1. 2x90 groups memory function;
2. Average calculating for the latest 3 times measurement value;
3. Blood pressure classification (WHO) indicator;
4. Irregular heartbeat (IHB) indicator;
5. Year/month/date/time function;
6. Automatic power-off in 3 minutes;
7. Medical CE approval, RoHs, REACH, PAHs, Phthalates compliance.
Competitive Advantage:
1. 90 groups memory each user, 2 users total 180 memory
2. liner discharge valve
Description:
1. Double use, each 90 groups of automatic memory
2. Date/Time Set function
3. Indicating average of the latest 3 readings
4. Large LCD display
5. Alarm clock function
6. High pressure alarm
7. Low battery warning
8. Intelligent control measurement techniques