Product Details:
Payment & Shipping Terms:
|
Type: | Biochemical Analysis System | Color: | Grey And White |
---|---|---|---|
Cable: | Simultaneous 12-cahnnel | Function: | Automatic Measurement And Interpretation |
Measurement Full Disclosure: | Exercise ECG With ST And Rhythm Measurements | Gurantee: | 1 Year |
High Light: | portable ecg machines,handheld ecg machine |
Handheld Stress Test ECG Machine CV1200 With High Quality Treadmill / Ergometer
As a multi-function ECG Workstation, the iCV1200 ECG Acquisition Systems increase the stress test function, it will give you a totally new feeling, which will help you work swiftly, diagnose accurately and get to a new high level of your career. The ECG Acquisition Systems can work smoothly interfacing with treadmill and ergometer.
n 12 lead ST segment measurement point can be set and changed according to HR by user during data sampling
n Real time analyze HR,ST segment and their trends, real time display and print 12 leads simultaneous ECG
n Protocols can be edited flexibly to work with different manufacturers’ treadmills
n Recorded ECG data can be replayed, so it is very convenient for doctors to view the ECG changes
n Offer detailed data for all stages
n Offer average ECG waves for 12 leads and all stages, help doctor to see the changes among different stages
n Treadmill starts from zero speed to ensure safety of patient
n Auto control of the speed and incline of the treadmill
n Test heart rate dynamically and Give alarm signal automatically
n Can save large quantity of patient data which can be reviewed, frozen and analyzed by doctors at any time
n Unique anti-artifact protocols to ensure stable waves
n Real time print of many selectable formats, no special printing paper needed
n Capacity for processing and memorizing numerous data
Sampling: 1000Hz
Channels: 12
Sensitivity; 5/10/20mm/mV
Frequency Response: 0.05-250Hz(±3dB)
Common Mode Rejection: >60dB
Input Impedance: >5MΩ
Isolate Voltage: 4000V
Polarity voltage: ±300mV
Current leak :< 20μA
PC Interface: USB Connector
Dimensions: 15L×8W×2.5H cm
CV-1200 Specification | ||
System | Monitor | 17"colour,high resolution |
Operator interface | Standard alphanumeric PC keyboard, and mouse | |
Power requirement | 110/230V,50/60Hz | |
Battery | emergency ECG capability with uninterrupted internal power supply for up to 3 minutes | |
Operating system | Microsoft Windows XP, Ergometer, Treadmill, NIBP | |
Printing | Chart paper | Thermo reactive, Z-fold,width,A4 |
Paper speed | 12.5/25/50mm/sec | |
Sensitivity | 5/10/20mm/mV | |
Print format | 6/12 channel printout, | |
Technical Date | Frequency Response | |
Sampling rate | 1000Hz/ch | |
CMR | >90dB | |
Maximum Electrode Potential | +300mV DC | |
Isolation | 4000V | |
Current Leek | <10µA | |
Digital Resolution | 12 bits | |
Input range | +10 mV | |
Software optional | Automatic ECG measurements and interpretation, | |
Environment Condition | Temperature operating | 10 to 40 |
Temperature storage | -10 to 50 | |
Pressure operating | 860hPa to 1060hPa |