Portable 3 Parameters electronic 12.1”maternal home fetal heart monitor 152mm wide paper
12.1” color folding up screen
24 hours waveforms playback
9 crystal pulse wave Doppler transducer
152mm wide paper support US/International standard
Rechargeable Lithium battery for 4 hours work
Handle for easy carry
Optional Fetal Stimulator
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively
Strength: <5mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization.
Measurement range: 50~210 bpm
Alarm Range:
High limit: 160, 170, 180, 190 bpm
Low limit: 90, 100, 110, 120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)
b) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
c) NIBP-MEAN(2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)
or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual
ECG
CMRR: ≥90dB
Heart Rate Measurement and Alarm Range: 15-300bpm
Accuracy: ±1bpm
Heart Rate Average: 8 beats
Lead Selection: II
Input: 5-lead ECG cable
Sweep Speed: 25 mm/s
Amplitude Selection: x1/4, x1/2, x1, x2, x4
Frequency Response:
Monitoring: 0.5 to 35Hz (+0.4dB, 3.0dB)
Defibrillation Protection: 5kV test
Recovery Time Following Defibrillation: Less than 5 seconds
Temperature:
Measurement and Alarm Limit: 0-50℃
Probe: Skin surface
Unit: Celsius/Fahrenheit
Accuracy: ±0.1℃(25°C ~45°C), ±0.2°C(0°C ~25°C
or 45°C ~50°C)
Resolution: 0.1℃
Respiration
Measurement Mode: Thoracic Impedance
Respiration Rate: 0-150 bpm
Waveform Display Speed: 25mm/s
Warranty : two years .one year for accessories .
Dimension:35*32*8.5(cm)
Net weight:3.5kg
Gross weight: 6.5kg
Packing Size: 42*39*25(CM)
Two monitors in one carton, the size is : 52*43*41(cm)
Delivery date: one week after ordering
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play
back the data.
Power: a.c.100-240v, 50/60Hz or 16.8v Li-ION battery
Power Consumption: < 20W
Environment
Working environment: Temperature: +5℃ ~ +40℃
Humidity: < 85%
Atmospheric pressure: 86kPa ~ 106kPa
Transport and storage temperature: Temperature: -10℃ ~ +55℃
Humidity: < 93%
Atmospheric pressure: 86kPa ~ 106kPa
Transducer Acoustic Output:
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2